Featuring the
Burner
Direct Vent Freestanding Stove
Natural Gas or Propane
Vent Horizontally or Vertically
Standard Residential
Mobile Home Approved
Tested and Listed by
Omni-Test Laboratories, Inc.
Beaverton, Oregon
Report # 028 – S – 14 - 1
ANSI Z21.88
WARNING: If the information in these instructions is not followed exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.7
Do not touch any electrical switch; do not use any phone in your building.
Immediately call gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
This appliance may be installed as an OEM installation in a manufactured (mobile) home and
must be installed in accordance with the manufacturer’s instructions and the manufactured
home construction and safety standard, Title 24 CFR, Part 3280 or Standard for Installation in
Mobile Homes, CAN/CSA Z240 MH.
This appliance is only for use with the type(s) of gas indicated on the rating plate. A conversion
kit is supplied with the appliance.
Salish Owner’s Manual
Installer: After installation give this manual to the home-owner
and explain operation of this heater.
Copyright 2004, T.I. $10.00 100-01136 4040809
4800 Harbour Pointe Blvd. SW
Mukilteo, WA 98275
Vista de página 0
1 2 3 4 5 6 ... 35 36

Resumo do Conteúdo

Página 1 - Salish Owner’s Manual

Featuring the Burner• Direct Vent Freestanding Stove• Natural Gas or Propane• Vent Horizontally or Vertically• Standard Residential• Mobile H

Página 2 - Introduction

10 Installation (for qualified installers only)Travis Industries100-01136 4040809Approved Vent ConfigurationsRestrictor Position• A vent restrictor i

Página 3 - Table of Contents 3

Installation (for qualified installers only) 11Travis Industries 100-01136 4040809Vertical Terminations with 0, 2, or 4 45° OffsetsOffset Length Hor.

Página 4 - Safety Precautions

12 Installation (for qualified installers only)Travis Industries100-01136 4040809Approved Venting Configurations with a Horizontal Termination• If us

Página 5 - Safety Precautions 5

Installation (for qualified installers only) 13Travis Industries 100-01136 4040809 Vertical Terminations with Two or Three 90° Elbows• The terminatio

Página 6 - Specifications

14 Installation (for qualified installers only)Travis Industries100-01136 4040809Termination Requirements (see the illustration below)A Minimum 9&quo

Página 7 - ANSI/NFPA 70)

Installation (for qualified installers only) 15Travis Industries 100-01136 4040809Finalizing the Installation! Turn the gas control valve to “OFF” pr

Página 8 - Gas Line Installation

16 Installation (for qualified installers only)Travis Industries100-01136 4040809FINE TUNING THE EMBER-FYRE™ BURNEREach installation is affected by

Página 9 - Vent Requirements

Installation (for qualified installers only) 17Travis Industries 100-01136 4040809Opening the DoorOpen both the top and bottom latch.With the pawl fr

Página 10 - Approved Vent Configurations

18 Installation (for qualified installers only)Travis Industries100-01136 4040809Log Set and Coal InstallationStep 1 Install the logs (see the ill

Página 11 - Zero or Two 45° Offsets

Installation (for qualified installers only) 19Travis Industries 100-01136 4040809Step 2 Install the twigs and ember chunk (see the illustration b

Página 12 - Propane (LP)

2 IntroductionTravis Industries 100-01136 141100IntroductionWe welcome you as a new owner of a Salish Stove. In purchasing this heater you have joine

Página 13 - 100-01136 4040809

20 OperationTravis Industries 100-01136 4040809Safety NoticeRead this entire manual (especially the “Safety Precautions” on pages 4 and 5)before using

Página 14 - 11” Min

Operation 21Travis Industries 100-01136 4040809Starting The Pilot FlameThe pilot flame is required to ignite the mainburners (it also plays a safety r

Página 15 - Finalizing the Installation

22 OperationTravis Industries 100-01136 4040809Starting the Heater for the First TimeCleaning Gold SurfacesFingerprints or other marks left on gold su

Página 16 - Travis Industries

Operation 23Travis Industries 100-01136 4040809Adjusting the Blower SpeedThe blower helps transfer heat from the heater into the room. It will not tu

Página 17 - Opening the Door

24 MaintenanceTravis Industries 100-01136 4040809Cleaning Your HeaterWarning: Fingerprints or other marks left on the optional gold surface may become

Página 18 - Log Set and Coal Installation

Maintenance 25Travis Industries 100-01136 4040809Troubleshooting StepsProblem: Possible Cause: Remedy:Pilot Will Not FlameA gas shut off valve is turn

Página 19 - Place the ember

26 MaintenanceTravis Industries 100-01136 4040809How this Heater WorksWarning This heater was designed with safety as the primary concern. Many of th

Página 20 - Operation

Maintenance 27Travis Industries 100-01136 4040809Wiring Diagram120 Volt WiringMillivolt Wiring (for gas control valve)OrangeWhitePiezo IgniterThermopi

Página 21 - Operation 21

28 Safety LabelTravis Industries 100-01136 4040809The listing label is shown below for your records. It can be found inside the right side panel.Sali

Página 22 - ROOM TEMP

Limited 7 Year Warranty 29Travis Industries 100-01136 4040809To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclos

Página 23 - Operation 23

Table of Contents 3Travis Industries 100-01136 4040809IntroductionIntroduction...2Important Informa

Página 24 - Maintenance

30 Optional EquipmentTravis Industries 100-01136 4040809LP Conversion InstructionsInstall the conversion kit prior to installing the gas line to ensur

Página 25 - Maintenance 25

Optional Equipment 31Travis Industries 100-01136 40408093 Follow the directions below to replace the orifices.1/2" WrenchUse a 1/2” open end wren

Página 26

32 Optional EquipmentTravis Industries 100-01136 40408095 Install the logs andembers.6 Close door.7 Remove the regulatorfrom the front of thegas contr

Página 27 - Replacement Parts:

Optional Equipment 33Travis Industries 100-01136 4040809Fireback (part # 98500754)Follow the directions below to install the optional firebrick. Remo

Página 28 - 28 Safety Label

34 Optional EquipmentTravis Industries 100-01136 4040809Gold Grill (Part # 93005046)Follow the directions to the right to install theoptional gold gri

Página 29

Installation Addenda 35Travis Industries 100-01136 4040809ADDENDUM #1 Class A ChimneyConversion KitSimpson Duravent provides a conversion kit for thos

Página 30 - 30 Optional Equipment

36 IndexTravis Industries 100-01136 4040809Adjusting the Blower Speed...23Adjusting the Flame Height ...22A

Página 31

4 Safety PrecautionsTravis Industries 100-01136 4040809• IF YOU SMELL GAS:* Do not light any appliance* Extinguish any open flame* Do not touc

Página 32 - Optional Equipment

Safety Precautions 5Travis Industries 100-01136 4040809• Do not place clothing orother flammable items on ornear the heater. Becausethis heater can b

Página 33 - Optional Equipment 33

6 SpecificationsTravis Industries 100-01136 4040809Installation Options:• Freestanding Stove• Residential or Mobile Home• Horizontal or Vertical VentF

Página 34

Installation (for qualified installers only) 7Travis Industries 100-01136 4040809Installation Warnings! Failure to follow all of the requirements may

Página 35 - Installation Addenda 35

8 Installation (for qualified installers only)Travis Industries100-01136 4040809Heater Placement Requirements• Heater must be installed on a level su

Página 36 - 36 Index

Installation (for qualified installers only) 9Travis Industries 100-01136 4040809Vent Requirements! Always maintain the required 1” clearance (air sp